The availability of our on-site fully anechoic chamber allows us to reach a level of precision that is on par with the highest global standards. It is a 3D measurement system capable of performing precise far field and near field measurements. This allows us to rapidly develop, test and verify prototypes we designed. Same goes for products that we manufactured, we could easily test it making sure that it fulfills the exact requirements needed.
- Far Field Capability
- Near Field Capability
- Rapid Development
- Accurate Measurements
- Precise Results
Far Field Capability
Range
Low frequency: 130 MHz - 700 MHz
High frequency: 700 MHz - 6 GHz
High frequency: 700 MHz - 6 GHz
Tolerance
Low frequency: +/- 1.5 dB
High frequency: +/- 1.0 dB
High frequency: +/- 1.0 dB
Near Field Capability
Range
Low frequency: 130 MHz - 700 MHz
High frequency: 700 MHz - 2 GHz
High frequency: 700 MHz - 2 GHz
Tolerance
Low frequency: +/- 1.0 dB
High frequency: +/- 1.5 dB
High frequency: +/- 1.5 dB